You must check your ac remote batteries when your AC is not working or turning on. Replace the batteries if they are dead. If the batteries are in working condition, check the circuit breaker. If the circuit breaker is tripped, your AC won’t turn on. Reset the circuit breaker by flipping the switch off and then on.
Your AC will not blow cold air if a dirty air filter blocks the airflow of your unit. A dirty air filter can further freeze up the evaporator unit and limit the cooling power of your AC. Cleaning your air filter every 6 months will increase your ac units performance.
Your air conditioner can freeze up due to:
When the refrigerant in your air conditioner starts leaking, the temperature will vary, and the unit will not perform accurately. Refrigerant leaks can result in:
When you frequently turn on and off your air conditioner, the fan controls and compressor can wear out. The condenser fan motor, the compressor, and the blower motor make an electrical connection to start the unit. A connection problem can prevent the motor and compressor from turning on. You should check the electrical connections to determine the issue.
Water leaking outside from your AC on a hot or humid day, especially when the unit is running, is considered normal. It is also normal if the water leakage occurs outside in cool weather at a temperature of 60 degrees or less, as the unit can freeze up and leak water when it melts. Other reasons for your air conditioner to leak water outside, include:
An air conditioner can make different sounds depending on the type of problems. There are different reasons why your air conditioner is producing a variety of sounds:
The evaporator coil freezes when your air conditioner does not receive sufficient air needed for operation. A frozen evaporator coil can make your AC freeze up and stop working. Blocked vents and ducts, dirty filters, or a faulty fan can cause insufficient airflow in the system. A clean air filter is important to maximize airflow and indoor air quality.
The drain pipeline can also become clogged with dust, algae, and dirt. If water does not drain properly, mold, fungus, and mildew can develop. Also, gasses and bad odor can filter into your space. To prevent this, make sure your drain line is regularly maintained, cleaned, and inspected. Air conditioners which are not mounted level may not drain properly.
The air conditioner contains a thermostat sensor, located near the evaporator coil. The thermostat measures the air temperature in the evaporating coil and adjusts the cooling based on the condition of the room. If the sensor is forced out of position, the air conditioner can randomly turn on and off or cycle constantly. The sensor should be placed near the evaporator coil without touching each other. Adjust the sensor by bending the wire that holds it in position.
Contact us today to have your air conditioner problems fixed right away by our experienced HVAC contractors.
At Service Experts, no job is too big or small. We can repair any HVAC-R equipment and restaurant equipment, including food processors. If you have recently purchased a restaurant, commercial property, night club we can provide you with a consultation on equipment repairs.
We Cater to the following Industries: Golf Clubs, Restaurants, Hotels, Night Clubs, Guesthouses, Laundromats, Coffee Shops, Corporate Offices, Call Centres, Bakeries, Ice Cream Parlors
Filtered Water produces more ice blocks, decrease maintenance servicing and increases your ice machines life-span.
Preheating your expresso machine for a duration longer than the manufactures recommendation is advisable.
Run your washer on a hot cycle with no clothes or detergent in it ( only applicable to certain machines) once a week.
Adding an Evaporative Water Cooler to your ventilated space is more energy efficient, than adding an air-conditioner.
Operating your air-conditioner at 21 degrees Celsius will increase your air-conditioners life-span and decrease unexpected repairs.
With less door opening of your freezer room, you will decrease its energy consumption and increase its performance and lifespan.
Fit duct work to your soft serve machine and decrease heat generation in the area and will be lower in running cost than an air-conditioner.
Preheat the warming cabinet before placing the hot food inside to ensure it reaches the desired temperature more quickly and efficiently
Load glassware in the correct way, avoid overcrowding that could lead to damage or insufficient cleaning.
Always keep your mixer clean and dry of water. Before cleaning the mixer ensure that you have switched it off.
Overloading a fryer will cause the oil temperature to drop rapidly, affecting the quality of your product.
After cooking, clean your oven as soon as you can. This will make cleaning easier than cleaning it later.
Whether you need a repair or want to schedule installation, regular maintenance, or a special project, you can count on Service Experts fast response and fair, honest pricing.
© 2025 Created with INVERTING MARKETING